GLISTEN PC PRODUCT INFORMATION

FULL INSTRUCTIONS FOR USE

Please read and understand these instructions thoroughly.  Failure to do so can result in premature coating failure.

PRODUCT DESCRIPTION

Glisten PC is a high-gloss, rock-hard, water-clear topcoat designed for spray or brush application over all metal surfaces, including highly polished aluminum and chrome surfaces.  Glisten PC will not leave brush marks and will dry in less that 1 hour, but will take 3 to 4 days to reach maximum hardness.  When Glisten PC is first dry to the touch, it appears very soft.  Avoid touching it for several days until it becomes hard and tough.  Accidental contact could damage the surface before full cure has taken place.  Like many other POR-15 coatings, Glisten PC is a moisture-cured coating, which means it is strengthened by exposure to moisture.  It won’t crack, chip, peel or yellow and is very flexible as well.

NOTE FOR EXISTING GLISTEN PC USERS:  Our new improved 2002 Glisten PC formulation eliminates the need to wait 1 hour after mixing before applying.  You may use it as soon as it is mixed with the Hardener/Activator.  Also, recoating and curing times are now much shorter, and you will find it easier to brush and spray.  Pot life, however, is now greatly reduced down to 2 or 3 hours once mixed.  Mix only what you need for the job, and if you need more, just repeat the mixing procedure.

PRODUCT COMPOSITION

Your Glisten PC purchase consists of 2 items: 1) A paint can, labeled Glisten PC, which is the basic clear coat formulation, and 2) A smaller can, labeled Hardener/Activator.  Mix the two products together, following the directions on the can, by blending them in a separate, resealable container.  A clean glass jar works best.  Stir the combined contents thoroughly to get a complete mix, which will allow the two components to blend and the molecules to link together properly.  WARNING: Your can of Hardener/Activator is sealed tightly.  Remove lid carefully, cover with a paper towel while prying it off to avoid accidental spillage or splash.  Your Hardener/Activator is very sensitive to moisture and humidity, so try to open it in a dry area.  Keep your resin and hardener tightly capped when not in use; this is very important.

PARTIAL MIXES

You may mix partial quantities of Glisten PC for small jobs, and you may use any measuring device you happen to have around (coffee scoop, measuring spoons, cups, etc.).  All you have to do is follow this formula:  Mix 1 part Hardener/Activator with 4 parts Glisten PC.  Glisten PC can remain usable for up to 2 to 3 hours if the lid is kept on the mixed batch when not in use.

SURFACE PREPARATION

If the surface to be coated is freshly polished, that is to say, just a few hours old, then go straight to the directions for polished metals.  If the existing clear coat is badly damaged and oxidizing (coating is flaky, yellowing, and generally breaking down), the best method is to remove all old coatings and re-polish to the desired luster.  If the existing coating is largely intact, not yellowing or breaking down, polish the damaged area and burnish the rest of the coating with fine sandpaper or pad (1200 grade), or rubbing compound.  The surface can now be treated the same as a freshly polished surface.  To coat polished metals, such as aluminum, brass, copper, chrome, nickel, and silver, if the surface has not been polished within 24 hours, it should be buffed or polished to remove any surface oxidation which may have occurred.  The use of a polishing compound is advisable, not just a quick wipe with a clean rag.  NOTE:  If this step is missed, coating adhesion will be substantially less.  After polishing, wipe surface to be coated with POR-15 Solvent, which will remove 90% of the surface contamination.

AP 120 METAL PREP: THE KEY TO PERFECT ADHESION

Now that you have prepared and cleaned the surface, one step remains to ensure you’ll achieve perfect adhesion.  That involves using AP 120 Metal Prep, essential when attempting to coat a highly polished surface with Glisten PC.  You may use a brush or sprayer or foaming gun.  All metals should be at room temperature.  Never attempt to use AP 120 outside in hot weather or in direct sunlight.  AP 120 is a ready to use liquid.  Apply it to metal surfaces for 2 minutes, no longer, then rinse well with water and dry.  Avoid hard water where possible.  Surface to be coated must be bone-dry before painting.  Use of a heat gun on casting is advisable, especially in colder climates, to dry out the pores in the metal and insure the elimination of all moisture before painting.

APPLICATION

Apply a minimum of 2 full coats for general and automotive use and a minimum of 3 full coats for marine use.  Glisten PC may be applied with any type of brush.  It can also be rolled.  It will flow out immediately, eliminating brush marks.  Lay down a medium-covering coat.  Be careful to avoid runs.  Second coat may be applied when dry to the touch, usually 15 – 25 minutes later at 68oF (20oC), though applying 2nd coat may be left up to 2 days before recoated without sanding.  Thin only with Xylene (Xylol), if required.  Xylene or lacquer thinner may be used for cleanup.  You can thin Glisten PC up to 30%; though if you do you’ll need to apply more coats to achieve a solid dry film thickness.  NOTE:  When brushing a 2nd or 3rd coat, there may be surface tension created between the coats, which could cause an irregular surface.  Thinning the 2nd or 3rd coat slightly reduces surface tension and allows Glisten PC to drop and flow out well.  For best results, apply in temps of 65oF to 75oF (18oC – 24oC) with less than 70% humidity. 

IMPORTANT NOTE:  Though your finish may be dry to the touch in an hour or two, it will not be fully cured for at least 72 to 96 hours (3 to 4 days).  Consequently, you should plan in advance on how to protect the surface from dust.  Clean plastic sheeting is good for this job, but don’t allow the sheeting to touch your painted surface.  Spray Painting/Spray Booths:  Your spraying area should be dust free and clean, with the appropriate exhaust equipment in place where applicable.  High pressure guns 50 – 70 psi, or HVLP guns 30 – 40 psi, but your own experience will quickly lead you to the proper adjustment.  A POR-15 Moisture and Oils disposable filter should be used when spraying Glisten PC, as trace oils or moisture through your spray gun can ruin your job.  Thin 10% to 20% if required.  Avoid temperatures over 83oF (28oC) where possible.  The best recommended spray booth temperature is 72oF (22oC) with 50% humidity, low airflow.  Remember, thinning rates are a guide only; you must also consider the type of gun, the air temperature, and humidity.  Glisten PC can be cut with regular compounds if you have a run or imperfections, but it is best to leave it for a week or two before cutting to make sure the coating is hard (runs may take longer to fully cure due to the added thickness). 

Note: If you are unfamiliar with Glisten PC or spraying clear coats, do not attempt to spray a large item first, but rather mix up a small amount and test what you are trying to achieve in a small area first.

Always remember that Glisten PC will not perform as specified until it has cured for a minimum of four (4) days at an average temperature of no less than 65oF (18oC).  Do not put alloy wheels, engine parts or the like into service before the four (4) day cure time is up.  Raising temperatures will not speed up the cure time.

Humidity should be 60% or lower when spraying Glisten PC because the higher humidity may cause it to set up too quickly before it has a chance to flow out evenly, and this could result in a wavy appearance.  This is especially true in high-humidity southern climates during the summer.  Whenever possible, spray in a humidity-controlled (air conditioned) environment.  Best temperature range is of 65oF to 75oF (18oC – 24oC).  If this is not possible, apply Glisten PC in the morning when the temperatures are at their lowest.  Glisten PC can be successfully applied in higher humidity, but temperatures must be below 77oF (25oC).  In temperatures over 86oF (30oC), the humidity must be low.  Avoid high humidity and high temperatures.

WARNINGS/CAUTIONS

Before opening cans (Glisten PC and Hardener/Activator), please read all warning labels and precautions, including those on the separate sheet.  If you are unfamiliar with Glisten PC or spraying clear coats, don’t attempt to spray a large area first, but rather mix up a small amount and test what you are trying to achieve in a small area first.  Avoid prolonged contact with skin and breathing vapor mist.  When mixed with Hardener/Activator, product contains Aliphatic Polyisocyanate, Xylol, Butyl Acetate, Propylene Glycol, and Ethyl Acetate.  Use only with adequate ventilation.  Use an organic vapor particulate respirator, NIOSH/MSHA approved, when brushing, and a positive pressure air supplied respirator (TC 23C NIOSH/MSHA) when spraying and until vapors have cleared the work area.  Do not breathe vapor mist.  Do not get into eyes or on skin.  Use of protective goggles is recommended.  Individuals with chronic respiratory problems or prior respiratory reactions to isocyanates must not be exposed to mists or vapors containing isocyanates.  FLAMMABLE: KEEP AWAY FROM OPEN FLAME.  Do not take internally.  FIRST AID:  If affected by inhalation of vapor or mist, remove to fresh air.  If breathing difficulty persists, consult a physician and have label information available.  EYE CONTACT:  Flush with water for 15 minutes and call physician.  SKIN CONTACT:  Wash with soap and water.  If swallowed, DO NOT INDUCE VOMITING.  KEEP OUT OF THE REACH OF CHILDREN.

Hazardous Ingredients: N-Butyl Acetate, Cas #123-86-4, Xylol, Cas #1330-20-7, PM Acetate, Cas #1108-65-6

IDEAL USES FOR GLISTEN PC:  As a protective coating on aluminum wheels, chrome bumpers, marine railings, chrome or aluminum covers, grills, handles, ornaments, lights, aluminum bumpers, alloy boats, alloy panels, etc.

Information contained herein is to our knowledge true and accurate, but all recommendations or suggestions are made without guarantee.  Since the conditions are beyond our control, RestoMotive Labs/POR-15 Inc. disclaims any liability incurred in connection with the use of its products and information contained herein.  No person is authorized or empowered to make any statement or recommendation not contained herein, and any such statement or recommendation so made shall not bind the Corporation.  Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing patents covering any materials or its use and no license implied or in fact is granted herein under the claims of any patents.